Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; qa_layer_9_from_layer_php has a deprecated constructor in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 3
of /home/abouaayt/public_html/aboutcivil/answers/qa-plugin/user-management/layer.php please send the detail of two way slab laying of steel diagram or in detaill - Civil Engineering Technical Questions Answers - Ask a Civil Engineer
  • Register
0 votes
please  send the detail of two way slab laying of steel  diagram  or in detaill

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
in Civil Engineering by  

1 Answer

0 votes
Bathroom/Kitchen (System of waterproofing treatment for Toilet / Kitchen sunken areas.)

Clean the RCC sunken slab and vertical portion of all dirt and loose material etc. with a wire brush.
Make corner fillets with polymer mortar of 25 X 25 mm size at all joints. Seal all pipe joint with polymer mortar. Then apply Tapecrete P-151 slurry coat on these pipe joints followed by wrapping it with fiberglass cloth again apply a second coat of Tapecrete slurry.

Moisten the RCC sunken slab and apply one coat of Tapecrete P –151 slurry coating.
Lay fiberglass cloth over the slurry coated surface.
Apply a second coat of Tapecrete P-151 slurry over the fiberglass laid surface.
Apply one coat of brush topping over the second coat of acrylic polymer modified cementitious slurry coating.
Provide a protective plaster over the treated surface as a protective layer, Figure 3.
The above systems of waterproofing has worked perfectly well in thousands of buildings and even various government agencies are considering to change their specification of conventional box type system for basements to chemical injection and acrylic polymer modified cementitious coating system.
by  

Related questions

0 votes
1 answer 635 views
635 views asked Jul 30, 2015 in Concrete Technology by mfby2k  
  • concrete

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • slab
0 votes
0 answers 766 views
766 views asked Aug 5, 2015 in Concrete Technology by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • slab
0 votes
1 answer 917 views
917 views asked Aug 20, 2015 in Civil Softwares by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • slab

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • bridge
0 votes
0 answers 551 views
551 views asked Aug 18, 2015 in Reinforced Concrete by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • design

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • slab
0 votes
2 answers 891 views
891 views asked Aug 18, 2015 in Reinforced Concrete by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • slab
...