Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; qa_layer_9_from_layer_php has a deprecated constructor in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 3
of /home/abouaayt/public_html/aboutcivil/answers/qa-plugin/user-management/layer.php RCC slab and Beam - Concrete mixture gone wrong (Used 2:5:7) - Civil Engineering Technical Questions Answers - Ask a Civil Engineer
  • Register

Welcome to Aboutcivil Q&A, where you can ask questions related to Civil Engineering and receive answers from other members of the community.

2.5k questions

1.1k answers

44 comments

44.3k users

0 votes
Site dimension is 30ft*40ft and we have total 14 columns in the plan.. We have lift planned in the plan too. Also our final roof height for each floor is 11" as per the plan. We are planning to construct Ground + 2floors of 1000sqft each on first and second floor. Ground floor we will have 1 BHK of approx 550 sqft and 2 car parking.
Construction was going fine but for our ground floor roof slab (or first floor bottom slab), contractor used wrong concrete mixture of 2:5:7(Cememnt: Sand: agregates) instead of M20 (1:1.5:3 ratio). Now we are not sure whether our RCC slab and beam safe for constructing first and second floors.

How to check whether the RCC slab and beam is safe and can we construct first and second floor?

Who will do the core cutting testing in bangalore and what is the contact details?

What additional measures to be taken to correct the wrong concrete misture ration. Can we plan steel bars as beams and/or additional columns to ensure that the structure supports the required load?

RCC slab was only put yesterday (27-Sep-2015) and we are very worried about this. Do we nede to break the RCC slab and do again?

Please advise and my contact number is 96111 00513 and please request you to provide the required advise to correct the mistake made by the contractor.

Thanks and Regards
Darshan
in Reinforced Concrete by  

1 Answer

0 votes
You have put very less grade concrete compared to the design mix. I think, it is not vise to brake the structure. Let it to gain the strength. If you can modify the structure, you can solve the problem.

You may  construct load bearing walls to transfer the beam loads to foundations and through the columns. Even for slabs you may do the same. Where ever you can not construct or support larger spans, It is better to have additional columns for supporting the structure.

http://structuraldesignbs.blogspot.com/
by  

Related questions

0 votes
1 answer 588 views
588 views asked Aug 5, 2015 in Building Construction by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • truss

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • construction

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • foundation

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • code
0 votes
0 answers 301 views
301 views asked Aug 5, 2015 in Reinforced Concrete by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • rcc
0 votes
0 answers 559 views
559 views asked Aug 17, 2015 in Reinforced Concrete by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • beam

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • shear
...