what is the comparison between ultimate strength design method and allowable stress method
in Structural Engineering by  

2 Answers

0 votes
Hai khan,Ultimate design method means we have to take failure load for design.so that structure will be used as optimum.but  some disadvantages are  there.In allowable stress method we have to use the allowable load for design that means we will take the yield strength of materials for design.so it will be more safer than that method...now a days we are not using that two methods.Limit State Design method is now adays wr are doing in India.
by  
0 votes
the first one is design based on ultimate limit of failure of structure and the other one is based on higher factor of safety so that the stucture will not fail even due to anticipated expected load on the structure...ultimate method is the least and most economocal way of design sturctures like building are based on this method while structures like chimney,dam which are heavy and typical is design on allowable stress method...
in ultimate strength method a partial factor of safety is applied both to material strength and design load ...while in allowable stress method the factor of safety is applied to material strength only  thus curtailing stresses and hence is known as allowable stress method.
by  

Related questions

0 votes
3 answers 2.8k views
0 votes
0 answers 576 views
576 views asked Aug 11, 2015 in Reinforced Concrete by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • civil
0 votes
1 answer 478 views
478 views asked Jul 6, 2015 in Structural Engineering by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • structure
0 votes
0 answers 374 views
374 views asked Aug 4, 2015 in Structural Engineering by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • structure
+1 vote
0 answers 1.5k views
1.5k views asked Aug 20, 2015 in Civil Engineering by mfby2k  

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • copper

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • pipe

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • shear

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • stress

  • Warning: count(): Parameter must be an array or an object that implements Countable in /home/abouaayt/public_html/aboutcivil/answers/qa-include/qa-base.php(720) : eval()'d code on line 12
  • rcc
...